← Back to Archive Index

EVMonitor.info Archive
This article is part of an archived collection from Nikolay Shishkov's blog about first-generation electric vehicles, battery maintenance, modifications, and repairs. Nikolay was an EV pioneer who passed away in 2025. His technical knowledge and generous sharing of information continues to help the EV community.

Graphing of a charging of Think A306

By Nikolay Shishkov • March 21, 2016

charginggraphlogThink A306think evZebra battery

Edit @2016-04-01: Updated with a corrected graph.

I took this log during a charging from about 35% to full on a Think City A306 with Zebra battery. The battery was relatively new.

To ease the reading of the graph: the battery current is between 0A and -4.2A, SOC is between 40% and 100%, battery temperature 240C and 250C, battery voltage 369V and 384V.

Feel free to post comments/questions.

← Back to Archive Index